Wall Construction Types
Exterior Coverings:
0.5-in lapped wood siding
1-in stucco finish
0.125-in vinyl siding
0.125-in aluminum siding
4-in face brick veneer
Wood Frame Wall Construction:
exterior covering
0.625-in plywood sheathing
3.5-in wood studs @ 16 in o.c.
3.5-in vertical air spaces + mineral fiber batt insulation
0.5-in gypsum wallboard
Wood Frame Walls with Expanded Polystyrene Sheathing:
exterior covering
0.5-in fiberboard sheathing
1-in expanded polystyrene insulation
3.5-in wood studs @ 16 in o.c.
3.5-in vertical air spaces + mineral fiber batt insulation
0.5-in gypsum wallboard
Wood Frame Walls with Optimum Value Engineering:
exterior covering
0.5-in fiberboard sheathing
5.5-in wood studs @ 24 in o.c.
5.5-in mineral fiber batt insulation
0.5-in gypsum wallboard
Structural Brick Walls:
8-in common structural brick
(0-2)-in expanded polystyrene insulation
0.75-in wood furring
0.75-in vertical air spaces
0.5-in gypsum wallboard
Concrete Block Walls:
exterior covering
8-in concrete block
5-in vertical air spaces
0.75-in wood furring
0.75-in vertical air spaces + fiberglass fill wall insulation
0.5-in gypsum wallboard
Straw Bale Walls:
1-in stucco finish
23-in straw bale
1-in stucco finish
Effective R-values:
The Home Energy Scoring Tool differs from Home Energy Saver Pro and Consumer in the wall types included.
Types not included in the Scoring tool are:
Wood Frame w/ Insulated Headers
Wood Frame w/ Insulated Headers & EPS
Wood Frame EPS Optimum Value Engineering
Additional types included in the Scoring Tool and the associated construction codes:
Stone => use the same insulation levels as for "Concrete Block"
Wood Frame with Asbestos, Fiber Cement, Composite Shingle or Masonite siding => use the same insulation levels as for standard wood siding.