Window & Skylight Construction Types

There are 18 default window and skylight construction assemblies. 


Vertical Windows Skylights (20 degrees slope)
Name U (SI) U (IP) SHGC U (SI) U (IP) SHGC
Single-pane, clear, al 6.76 1.19 0.78 7.66 1.35 0.78
Single-pane, clear w/v 5.24 0.92 0.72 6.10 1.08 0.72
Single-pane, tinted, al 6.76 1.19 0.67 7.66 1.35 0.68
Single-pane, clear w/v 5.24 0.92 0.72 6.10 1.08 0.72
Double, clear, al 4.37 0.77 0.70 4.66 0.82 0.70
Double, clear, ATB 3.24 0.57 0.67 3.53 0.62 0.67
Double, clear, w/v 2.94 0.52 0.64 3.22 0.57 0.64
Double, tint, al 4.27 0.75 0.58 4.71 0.83 0.58
Double, tint, ATB 3.15 0.55 0.55 3.59 0.63 0.56
Double, tint, w/v 2.85 0.50 0.53 3.27 0.58 0.53
Double, high solar gain low-e (e=0.07 on surface 3),w/v 2.07 0.36 0.56 2.67 0.47 0.57
Double, high solar gain low-e (e=0.07 on surface 3), argon, ATB 2.11 0.37 0.59 2.66 0.47 0.60
Double, high solar gain low-e (e=0.07 on surface 3), argon, w/v 1.86 0.33 0.57 2.39 0.42 0.57
Double, low solar gain low-e (e=0.02 on surface 2), al 3.38 0.59 0.28 4.02 0.71 0.28
Double, low solar gain low-e (e=0.02 on surface 2), ATB 2.25 0.40 0.25 2.90 0.51 0.26
Double, low solar gain low-e (e=0.02 on surface 2), w/v 2.00 0.35 0.24 2.61 0.46 0.24
Double, low solar gain low-e (e=0.02 on surface 2), argon, improved w/v 1.48 0.26 0.23 2.02 0.36 0.24
Triple, low solar gain low-e (e=0.02 on surfaces 3 and 5, argon, improved w/v 0.99 0.17 0.21 1.11 0.20 0.21